int __stdcall SM_GetAnalogInputConfig ( SM_HANDLE  handle,
unsigned char *  reference,
unsigned char *  mode 
)

Gets the device's analog configuration.

Parameters
[in]handleValid handle returned by SM_Open().
[in]referenceAnalog to digital reference point.
[in]modeDevice input mode.
Return values
0Successful completion.
-1Invalid SeaMAX handle.
-2Invalid reference or mode parameter. May not be null.
-3Connection is not established. Check the provided Connection object state.
-4Modbus: Read error waiting for response. Unknown Modbus exception.
-5Modbus: Illegal Modbus Function (Modbus Exception 0x01).
-6Modbus: Illegal Data Address (Modbus Exception 0x02).
-7Modbus: Illegal Data Value (Modbus Exception 0x03).
-8Modbus: CRC was invalid. Possible communications problem.

Gets the I/O device's offset reference and A/D channel mode. The reference parameter represents which source each analog input is compared against. The mode parameter is the overall configuration of the channels and whether they are singled ended or paired.

For more information on the returned parameter values, see A/D Voltage Reference values and A/D Channel Modes.

Note
This method only applies to certain models. See SeaMAX by Sealevel Model Number for details.
 
 
Generated on Mon Nov 26 2018.